Author(s) Menown I.B.A.; De Silva R.; Mitra R.; Balachandran K.; More R. et al.
Source European Heart Journal; Oct 2019; vol. 40 ; p. 1744 Background: Thin stent struts may be associated with reduced vessel injury and use of biodegradable polymers may further improve long term outcomes. However, data with earlier stents has been inconsistent; thus further studies with newer devices are needed. Purpose(s): To evaluate the efficacy and safety of a new ultra-thin (65um) strut cobalt chromium sirolimus-eluting stent with a hybrid design (closed cell at ends and open cells in middle to reduce edge injury and optimise conformability) in all-comers patients undergoing percutaneous coronary intervention (PCI). Method(s): We enrolled 752 patients from 14 sites undergoing PCI into a prospective, non-randomised, multi-centre, open-label, observational registry. Inclusion of patients with complex anatomy (long stent lengths, bifurcations and chronic total occlusions) was encouraged. Clinical follow-up was scheduled at 1, 9, 12 and 24 months. The primary endpoint was incidence of major adverse cardiac events (MACE)-cardiac death, non-fatal myocardial infarction (MI), or target vessel revascularization (TVR)-at 9 months. Result(s): Mean patient age was 64.7+/-12.2 years, 20.7% had diabetes, 58.8% had dyslipidaemia, 40.4% had multi-vessel disease, 22% had previous PCI, 4.7% had previous coronary-artery bypass graft, and 19.6% had a clinical history of previous MI. Mean lesion length was 25.7+/-17.3 mm. The primary endpoint of cumulative MACE up to 9 months (from 624 patients reaching 9 months follow-up) occurred in 12 patients (1.92%), including 6 (0.96%) cardiac death, 5 (0.80%) MI and 6 (0.96%) clinically indicated TVR. Definite stent thrombosis was reported in 3 patients (0.48%) and probable stent thrombosis in 2 patients (0.32%). Conclusion(s): Use of an ultra-thin strut biodegradable polymer sirolimuseluting stent in all-comers patients undergoing PCI was associated with good clinical efficacy and safety.
0 Comments
Leave a Reply. |
The following databases were searched:
EMBASE, MEDLINE, PsycINFO, BNI, CINAHL, to find ELHT staff publications Specialties
All
Archives
August 2022
|
Learning Centre Library
Royal Blackburn Teaching Hospital 01254 734312 or Ext 84312 library.blackburn@elht.nhs.uk Find us |
Mackenzie Library
Burnley General Teaching Hospital 01282 803114 or Ext. 13114 library.burnley@elht.nhs.uk Find us |
Staffed Opening Hours
Mon 08:30-16:30 Tue 08:30-16:30 Wed 08:30-16:30 Thu 08:30-16:30 Fri 08:30-16:00 24/7 access to both libraries is available - please see library staff
|